TEAM Climate Monitoring Protocol 3.0
12
Figure 1. Workflow that illustrates the steps for siting the climate station. In Level 1, all sensors
(precipitation, temperature, relative humidity and solar radiation) are together at the same location. In Level
2, the station is sited using the requirements of the temperature/RH and precipitation sensors and the
radiation sensor is located at an alternate point within 100 m of the climate station and connected to the same
data logger. In Level 3 the radiation sensor is located at a separate location (> 100 m away from the other
sensors) and has a dedicated data logger and power source, separate from the rest of the sensors. If no
clearings are available that fulfill Level 2 siting then locate the station in the site that most closely resembles
Level 2 requirements and document site conditions carefully (Level 4).