AWG 64 MB MEMORY CARD FOR WII Specifiche Pagina 1

Navigare online o scaricare Specifiche per Misurazione, test & controllo AWG 64 MB MEMORY CARD FOR WII. AWG 64 MB MEMORY CARD FOR WII Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 62
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Tropical Ecology, Assessment, and Monitoring Network
Climate Monitoring Protocol
Version 3.0
Cite as: TEAM Network. 2010. Climate Monitoring Protocol, v. 3.0. Tropical Ecology,
Assessment and Monitoring Network, Science and Knowledge Division, Conservation
International, Arlington, VA, USA.
Vedere la pagina 0
1 2 3 4 5 6 ... 61 62

Sommario

Pagina 1

Tropical Ecology, Assessment, and Monitoring Network Climate Monitoring Protocol Version 3.0 Cite as: TEAM Network. 2010. Climate Moni

Pagina 2

TEAM Climate Monitoring Protocol 3.0 10 • Ideally, the climate station should be located in a clearing with an unobstructed view of the sky (n

Pagina 3 - Table of Contents

TEAM Climate Monitoring Protocol 3.0 11 4.2 Level 1 Siting Ideally, and to fulfill the requirements of the global solar radiation sensor, the

Pagina 4 - 1 INTRODUCTION AND SCOPE

TEAM Climate Monitoring Protocol 3.0 12 Figure 1. Workflow that illustrates the steps for siting the climate station. In Level 1, all sensors

Pagina 5

TEAM Climate Monitoring Protocol 3.0 13 4.3 Level 2 Siting Since the requirements of the solar radiation sensor are difficult to meet in many

Pagina 6 - 2 GOALS AND IMPLEMENTATION

TEAM Climate Monitoring Protocol 3.0 14 The climate equipment itself requires an area of 60-65 m2, where the tower and sensors will be installe

Pagina 7 - 3.3 Sensors

TEAM Climate Monitoring Protocol 3.0 15 Figure 3. Workflow describing the main steps for siting the climate station (Level 2).

Pagina 8 - 3.4 Power supply

TEAM Climate Monitoring Protocol 3.0 16 Figure 4. Diagram describing siting process. A. Initial location is at least 4H units away from the ta

Pagina 9

TEAM Climate Monitoring Protocol 3.0 17 4.3.2 Siting the Radiation Sensor There are two possibilities for locating the radiation sensor based

Pagina 10

TEAM Climate Monitoring Protocol 3.0 18 4.4 Level 3 Siting If the radiation sensor cannot be located within the vicinity of the main climate s

Pagina 11 - 4.2 Level 1 Siting

TEAM Climate Monitoring Protocol 3.0 19 A standardized list of equipment and whether it should be acquired as part of Level 1, 2, or 3 siting i

Pagina 12

TEAM Climate Monitoring Protocol 3.0 2 Acknowledgments This protocol and all other TEAM protocols are collective works. They were developed a

Pagina 13 - 4.3 Level 2 Siting

TEAM Climate Monitoring Protocol 3.0 20 2. Take pictures: This information is crucial to get accurate information about the site where the sta

Pagina 14

TEAM Climate Monitoring Protocol 3.0 21 5.1 Testing all the instrumentation upon receipt As soon as the equipment is received, the data logger

Pagina 15

TEAM Climate Monitoring Protocol 3.0 22 Figure 5. Main wiring diagram of the climate station showing the connections between main components.

Pagina 16

TEAM Climate Monitoring Protocol 3.0 23 Figure 6. Main components of the CR1000 data logger. Figure 7. Main screen of PC200W software.

Pagina 17

TEAM Climate Monitoring Protocol 3.0 24 7. Establish communication with the data logger: Select CR1000 on the left and hit the Connect button

Pagina 18 - 4.6 Ordering the Equipment

TEAM Climate Monitoring Protocol 3.0 25 each TEAM Site and are required for use. Any changes will be done by the Network Office which will als

Pagina 19

TEAM Climate Monitoring Protocol 3.0 26 Collection of test data: Once the sensors are all connected, turn the data logger back on and wait for

Pagina 20

TEAM Climate Monitoring Protocol 3.0 27 5.2.1 Base Installation The tower is based on top of a concrete foundation that must be installed at t

Pagina 21

TEAM Climate Monitoring Protocol 3.0 28 Install the charge regulator: Before mounting the solar panel to the tower, install the power regulato

Pagina 22

TEAM Climate Monitoring Protocol 3.0 29 5.5.1 Vaisala HMP45C Temperature/RH sensor Two HMP45C are housed inside a MetOne Aspirated Radiation S

Pagina 23

TEAM Climate Monitoring Protocol 3.0 3 Table of Contents 1! INTRODUCTION AND SCOPE ...

Pagina 24

TEAM Climate Monitoring Protocol 3.0 30 Replace the top cover of the cabling box: Once the sensors are connected to the cabling box replace the

Pagina 25

TEAM Climate Monitoring Protocol 3.0 31 Figure 11. Diagram showing the correct way to connect the power cable terminals to the data logger. 5

Pagina 26

TEAM Climate Monitoring Protocol 3.0 32 Pyranometer at an alternate location: Follow the same steps for pyranometers that will be installed at

Pagina 27

TEAM Climate Monitoring Protocol 3.0 33 5.6 Finishing steps 5.6.1 Secure the weather resistant enclosure Once all the sensors and power sourc

Pagina 28 - 5.5 Installing the sensors

TEAM Climate Monitoring Protocol 3.0 34 Convert the file from the card into a readable format: • From the PC200W tools menu, select Card Conv

Pagina 29

TEAM Climate Monitoring Protocol 3.0 35 6.1.2 Retrieving the Data from a dedicated data logger (Level 3). TO BE COMPLETED. 6.1.3 Extract the

Pagina 30

TEAM Climate Monitoring Protocol 3.0 36 6.2.1 Measure and record the event After the event has passed, measure the rainfall using the enclosed

Pagina 31 - Campbell 2008)

TEAM Climate Monitoring Protocol 3.0 37 6.3.3 Enclosure Maintenance Check the integrity of the enclosure at least monthly (preferably every tw

Pagina 32

TEAM Climate Monitoring Protocol 3.0 38 Precipitation gauge (TB4): Inspect the precipitation gauge every time the station is visited. Remove an

Pagina 33 - 5.6 Finishing steps

TEAM Climate Monitoring Protocol 3.0 39 System/Sensor Activity Frequency Climate station core area/fence Remove debris, general maintenance Mon

Pagina 34 - 6.1 Data Retrieval

TEAM Climate Monitoring Protocol 3.0 4 1 INTRODUCTION AND SCOPE Climate change has been identified as one of the main threats to humanity and

Pagina 35

TEAM Climate Monitoring Protocol 3.0 40 6.4.1 Temperature/RH sensor (Vaisala HMP45C) The sensor head should be recalibrated every two years (t

Pagina 36 - 6.3 Regular Maintenance

TEAM Climate Monitoring Protocol 3.0 41 Figure 13. Diagram illustrating operation and calibration schedules for Temperature/RH sensors (also

Pagina 37

TEAM Climate Monitoring Protocol 3.0 42 6.4.3 Solar radiation (LI 200X) The Licor LI 200X should be sent out for calibration every 2 years. As

Pagina 38

TEAM Climate Monitoring Protocol 3.0 43 Submit information to the TEAM portal Solar Radiation (LI 200X) Sent to manufacturer for calibration.

Pagina 39 - 6.4 Sensor Calibration

TEAM Climate Monitoring Protocol 3.0 44 NRC 1999. Adequacy of Climate Observing Systems. Panel on climate observing systems status. Climate Res

Pagina 40

TEAM Climate Monitoring Protocol 3.0 45 Calibration. A process to adjust measurements from a sensor to a universally defined standard of measur

Pagina 41

TEAM Climate Monitoring Protocol 3.0 46 Memory Card. Device to store climate data collected by the data logger (usually a 32-64 MB Compact Flas

Pagina 42

TEAM Climate Monitoring Protocol 3.0 47 Sensor Calibration Form. Field form to keep track of sensor calibration information such as date when s

Pagina 43 - 7 REFERENCES CITED

9 APPENDIX A.1. MAIN EQUIPMENT LIST (Continues into next page) Category Equipment Description Number Supplier Model ID Level 1 &4 Level 2 Level

Pagina 44 - 8 GLOSSARY

TEAM Climate Monitoring Protocol 3.0 49 Category Equipment Description Number Supplier Model ID Level 1 &4 Level 2 Level 3 12V Charging r

Pagina 45

TEAM Climate Monitoring Protocol 3.0 5 5. Integrated Environmental Assessment: Anticipate the use of the data in the development of environmen

Pagina 46

10 APPENDIX A.2. SITE METADATA FIELD FORM

Pagina 47

TEAM Climate Monitoring Protocol 3.0 51

Pagina 48 - (Continues into next page)

TEAM Climate Monitoring Protocol 3.0 52

Pagina 49

TEAM Climate Monitoring Protocol 3.0 53 11 APPENDIX A.3. CLIMATE PROTOCOL MAINTENANCE LOG

Pagina 50

TEAM Climate Monitoring Protocol 3.0 54

Pagina 51

TEAM Climate Monitoring Protocol 3.0 55

Pagina 52

TEAM Climate Monitoring Protocol 3.0 56 12 APPENDIX A.4. SENSOR CALIBRATION FORM

Pagina 53

TEAM Climate Monitoring Protocol 3.0 57

Pagina 54

TEAM Climate Monitoring Protocol 3.0 58 13 APPENDIX A.5. SENSOR CALIBRATION METADATA FORM

Pagina 55

TEAM Climate Monitoring Protocol 3.0 59 Climate Monitoring ProtocolSensor Calibration Metadata Formv. 1.0SENSOR SENT OUT FOR CALIBRATIONSen

Pagina 56

TEAM Climate Monitoring Protocol 3.0 6 This document describes in detail all the necessary steps to setup and implement the TEAM Climate Monito

Pagina 57

TEAM Climate Monitoring Protocol 3.0 60 14 APPENDIX A.6. WIRING DIAGRAMS

Pagina 58

TEAM Climate Monitoring Protocol 3.0 61 (Shield cabling diagram shown in next page)

Pagina 59 - Sensor Calibration Metadata

TEAM Climate Monitoring Protocol 3.0 62 SHIELD CABLING DIAGRAM

Pagina 60

TEAM Climate Monitoring Protocol 3.0 7 3 BASIC EQUIPMENT DESCRIPTION In order to be an adequate tool for monitoring climate, the sensors and e

Pagina 61

TEAM Climate Monitoring Protocol 3.0 8 3.3.1 Temperature – Relative Humidity Sensor Vaisala HMP45C The TEAM Climate Protocol uses the Vaisala

Pagina 62

TEAM Climate Monitoring Protocol 3.0 9 Variable Range Resolution Mode of measurement /observation Required measurement uncertainty Output aver

Commenti su questo manuale

Nessun commento